Quality Kipor Generators - with warranties and backup service

Email your requirements to : sales@eurointernational.co.za

Tel : 011-022-6550/1/2

  • KIPOR General Generators KDE6700TA 5kVa

    KIPOR General Generators KDE6700TA

    Powerful KM186FAGET diesel engine
    Low Oil Alarm System
    New AVR
    Electrical starter
    Easier and more convenient electric starter

    Overview

    Rated frequency of 50 Hz
    Rated output of 4.5 kVa
    Pole Number 2
    General Panel Type
    Two receptables
    Open frame Structure type
    Engine Model KM186FAGET


    Strong Power


    All generator sets are equipped with KIPOR four-stroke engines.


    Low Noise Running


    High effective combustion system ensures complete combustion, Besides, a large silencer dampens exhaust noise and engine sounds which are contained by a double-wall structure and absorbed by a liner.


    Digital Control Panel


    All the control units of the generator sets are on one panel, a monitor of the panel will display the real-time working data of the generator set such as its output voltage and current etc. Besides, the running trouble of the generator will also be displayed on the panel.


    Low Oil Alarm System


    Before the oil level drops to the limited level, the generator set will stop automatically. The whole set can be restarted only if the oil is refilled.


    Application of New AVR


    The AVR (Automatic Voltage Regulator) not only can smooth the output but also can provide reasonable protection against the overload of the whole set, thus avoid damage to the set.


    Advanced Alternator Winding


    Waveform distortion is kept at a minimum level and the output is stable. The winding design protects the generator from short circuits and provides a stable output while running inductive loads.


    ATS (Automatic Transfer Switch)


    On the inheriting of the original general-purpose generator set, KIPOR diesel generator sets with digital control panel can be equipped with a made ATS(automatic transfer switch). ATS, in its preset intervals, can automatically check and monitor the running of the genset to ensure the genset in good working condition. Meanwhile, ATS will monitor the utility power, if utility power fails or the voltage and frequency of the utility power become abnormal, ATS will give commands to start the genset automatically.



    Model KDE6700TA
    Rated frequency (Hz) 50 60
    Rated output (kVA) 4.5 5.0
    Max. output (kVA) 5.0 5.5
    Rated Voltage (V) 115/230 120/240
    Rated current (A) 39.1/19.6 41.7/20.8
    Rated rotation speed (r/min) 3000 3600
    Phase NO. Single phase
    Power factor (Cos Φ) 1.0
    Insulation Grade B
    Pole number 2
    Excitation mode Self-excitation & constant voltage (AVR)
    Panel Type General Panel
    Voltage (V) 115/230 120/240
    Receptacle Two receptacles
    Connection pole Without
    DC12V output DC receptacle output
    Overall dimension(L×W×H)(mm) 930X535X742
    Dry weight(kg) 170
    Working assorting weight (Kg) 185
    Noise level(7m)dB(A) 72
    Structure type Silent
    Engine Model KM186FAGET
    Engine Type Single cylinder, vertical, four-stroke, direct injection
    Cylinder NO.-bore×stroke (mm) 1-86×72
    Displacement (ml) 418
    Rated power [KW/(r/min)] 5.7/3000 6.3/3600
    Compression ratio 19:1
    Rated rotation speed (r/min) 3000 3600
    Combustion system Direct injection
    Cooling system Air cooled
    Lubrication system Pressure splashed
    Starting system Electric starter
    Fuel type 0#(summer)-10#(winter)-35#(chillness)diesel
    Lube oil brand CD grade or SAE10W-30,15W-40
    Capacity of cooling water (L) Without
    Lube capacity (L) 1.65
    Starting motor capacity (V-kW) 12V 0.8kW
    Charging generator capacity (V-A) 12V 3A
    Battery capacity (V-Ah) 12V 36Ah
    Fuel consumption (g/kW.h) ≤360
    Fuel tank capacity (L) 15
    Continuous running time (hr) 6


    KIPOR General purpose generators South Africa

  • KIPOR Super Silent Generators KDE12STA 8.5 kVa 220V

    KIPOR Super Silent Generators KDE12STA

    Digital Control Panel
    Low Oil Alarm System
    Application of New AVR
    Advanced Alternator Winding
    Automatic Transfer Switch
    Equiped with KIPOR four-stroke engine

    Overview

    Rated frequency 50 Hz
    Rated output 8.5 kVa
    Single phase
    Pole number 2
    Digital Panel type
    Dry weight 310kg
    Engine Model KM2V80G



    Strong Power

    All generator sets are equipped with KIPOR four-stroke engines.


    Low Noise Running

    High effective combustion system ensures complete combustion, Besides, a large silencer dampens exhaust noise and engine sounds which are contained by a double-wall structure and absorbed by a liner.


    Digital Control Panel

    All the control units of the generator sets are on one panel, a monitor of the panel will display the real-time working data of the generator set such as its output voltage and current etc. Besides, the running trouble of the generator will also be displayed on the panel.


    Low Oil Alarm System

    Before the oil level drops to the limited level, the generator set will stop automatically. The whole set can be restarted only if the oil is refilled.


    Application of New AVR

    The AVR (Automatic Voltage Regulator) not only can smooth the output but also can provide reasonable protection against the overload of the whole set, thus avoid damage to the set.


    Advanced Alternator Winding

    Waveform distortion is kept at a minimum level and the output is stable. The winding design protects the generator from short circuits and provides a stable output while running inductive loads.


    ATS (Automatic Transfer Switch)

    On the inheriting of the original general-purpose generator set, KIPOR diesel generator sets with digital control panel can be equipped with a made ATS(automatic transfer switch). ATS, in its preset intervals, can automatically check and monitor the running of the genset to ensure the genset in good working condition. Meanwhile, ATS will monitor the utility power, if utility power fails or the voltage and frequency of the utility power become abnormal, ATS will give commands to start the genset automatically.



    Model KDE12STA
    Rated frequency (Hz) 50 60
    Rated output (kVA) 8.5 9.5
    Max. output (kVA) 9.5 10.5
    Rated Voltage (V) 115/230 120/240
    Rated current (A) 73.9/37 79.2/39.6
    Rated rotation speed (r/min) 3000 3600
    Phase NO. Single phase
    Power factor (Cos Φ) 1.0
    Insulation Grade B
    Pole number 2
    Excitation mode Self-excitation & constant voltage (AV R)
    Panel Type Digital Panel
    Voltage (V) 115/230 120/240
    Receptacle Two receptacles
    Connection pole With
    DC12V output Without
    Overall dimension(L×W×H)(mm) 1350X795X850 1350X650X760(without wheels)
    Dry weight(kg) 310
    Working assorting weight (Kg) 345
    Noise level(7m)dB(A) 72
    Structure type Super Silent
    Engine Model KM2V80G
    Engine Type Two-cylinder, v-twin, water-cooled, four-stroke, swirl chamber
    Cylinder NO.-bore×stroke (mm) 2-80×79
    Displacement (ml) 794
    Rated power [KW/(r/min)] 12.5/3000 14.5/3600
    Compression ratio 23:1
    Rated rotation speed (r/min) 3000 3600
    Combustion system —
    Cooling system Water cooled
    Lubrication system Pressure splashed
    Starting system Electric starter
    Fuel type 0#(summer)-10#(winter)-35#(chillness)diesel
    Lube oil brand CD grade or SAE10W-30,15W-40
    Capacity of cooling water (L) Without
    Lube capacity (L) 2.27
    Starting motor capacity (V-kW) 12V 1.4kW
    Charging generator capacity (V-A) 12V 20A
    Battery capacity (V-Ah) 12V 36Ah
    Fuel consumption (g/kW.h) ≤340
    Fuel tank capacity (L) 26
    Continuous running time (hr) 7


    For all your KIPOR Super Silent Generator requirements in South Africa

  • KIPOR Industrial generators 100kVA – 3000kVA

    KIPOR Industrial generators 100kVA – 3000kVA
    Contact us for all industrial generator requirements.
    We offer a full solution to this sector as well as most requirements according to the customers specs.

    Industrial Generator


    If you are a business owner or manager - even if it's a small business - you should have a plan in place in case of an extended power outage. The fact is that long power outages can cause a substantial loss of money as well as a multitude of other problems for commercial and industrial businesses alike. For this reason, it is critical for most companies to consider purchasing industrial generators - or at the very least to have a plan in place should an extended power outage occur.


    In the industrial sector, lost revenue can be even more devastating when electrical power goes down. Manufacturing plants, chemical plants, oil & gas-related businesses and countless other industrial businesses cannot afford to lose power for any appreciable length of time. Down time means lost revenue - plain and simple. In addition, down time can put your business behind schedule - causing delays that will inconvenience your customers and damage your reputation. However, all of these problems may be avoided through the use of industrial generators.


    So how can business owners plan for extended power outages? You must ensure that you have industrial generators on site. There are multiple options available - it's just a matter of determining the right industrial generator for your particular business.


    Choosing which type of industrial generator is right for your company involves several factors. First, you need to determine your power needs - which includes both start-up wattage and continuous power wattage - and then you must ensure that you choose an industrial/commercial generator with enough capacity. Then you can choose the type of generator that best suits your needs.


    Regardless of which type of industrial generator you choose, one thing is plainly clear - it is much better to keep your business open than to be shut down due to loss of power. In the long run, industrial generators will pay for themselves many times over.


    In the commercial sector, losing power for even a few hours can be extremely costly for supermarkets, restaurants, banks, as well as every type of retail store, large or small. For any business in the food industry, you run the risk of refrigerated or frozen goods spoiling when a power outage lasts for more than a day. Restaurants and grocery stores are also susceptible to spoiled food and no customers, since your business may be shut down for the length of the power outage. All retail businesses will also suffer because many customers will assume you are closed or be turned away due to lack of power. In addition, your security systems will not operate, so your business is left vulnerable. When you consider all of these factors, the importance of industrial commercial generators becomes obvious.